WBS Active boiler and Pell burner kit
WBS Active boiler with a fitted Pell pellet burner for heating medium and large rooms using wood pellets. The boiler is adapted for pellet combustion with additional components that help the kit reach the required efficiency. Tested and approved to EN 303-5, class 5.
Key features
✓
Automatic ignition and pellet feed
✓
Ready-to-use pellet boiler kit
✓
Microprocessor controller
✓
Temperature sensor
✓
3 bar safety valve
WBS Active – Pell boiler components:
- Casing
- High-efficiency insulation
- Three-pass flue gas path
- Water jacket
- Combustion chamber
- Tray
- Burner flange
- Chimney
- Non-return damper fitted to the fan
Benefits
- Ready-to-use pellet boiler kit.
- WBS Active boiler adapted for pellet combustion with a fitted Pell burner, turbulators, an upper safety door and a mounting kit.
- Self-cleaning burner function.
- Heating system pump control.
- Domestic hot water pump control.
- Control via an external room thermostat.
- Boiler control based on buffer tank temperature.
- A temperature sensor monitors the boiler and the hot water cylinder.
- Two temperature sensors monitor buffer tank temperature.
The kit includes:
1 – WBS AC boiler
2 – Pell pellet burner
3 – Pellet feed auger
4 – Mounting kit
Available outputs, kW:
| KIT | CONTENTS |
|---|---|
| BURNIT WBS AC PELLET 20 | WBS AC 30 / PELL 30 |
| BURNIT WBS AC PELLET 25 | WBS AC 40 / PELL 30 |
| BURNIT WBS AC PELLET 35 | WBS AC 50 / PELL 40 |
| BURNIT WBS AC PELLET 50 | WBS AC 70 / PELL 70 |
| BURNIT WBS AC PELLET 60 | WBS AC 90 / PELL 70 |
| BURNIT WBS AC PELLET 60 + | WBS AC 90 + / PELL 70 |
Safety components:
- The curved burner feed tube prevents burn-back into the pellet hopper
- Thermostatic protection (80°C)
- 10 A fuse
- If power is interrupted, all settings are retained in the controller memory
- Safety heat exchanger
- 3 bar safety valve
FULL MODEL SPECIFICATIONS
Technical specifications
| Technical specifications | WBS – A 30 | WBS – AC 40 | WBS – AC 50 | WBS – AC 70 | WBS – AC 90 | |||
|---|---|---|---|---|---|---|---|---|
| Pell 30 | Pell 30 | Pell 40 | Pell 70 | Pell 70 | ||||
| Rated output | kW | 22 | 30 | 35 | 52 | 60 | ||
| Min. / max. output | kW | 6÷25 | 9÷32 | 10÷40 | 15÷65 | 18÷65 | ||
| Flue gas mass flow, | kg / s | 0, 005÷0, 013 | 0, 011÷0, 025 | 0, 007÷0, 021 | 0, 012÷0, 032 | 0, 010÷0, 031 | ||
| at min. / max. output | ||||||||
| Overall dimensions of | Height H | mm | 1235 | 1235 | 1235 | 1385 | 1385 | |
| WBS Active + Pell | Width L | 540 | 700 | 700 | 700 | 760 | ||
| Depth D | 1315 | 1315 | 1375 | 1495 | 1495 | |||
| Water jacket volume | L | 75 | 96 | 106 | 134 | 145 | ||
| Combustion chamber volume | L | 62 | 84 | 97 | 120 | 133 | ||
| Water jacket resistance, Δt=20 K | Pa / mbar | 9 / 0, 09 | 12 / 0, 12 | 14 / 0, 14 | 26 / 0, 26 | 20 / 0, 20 | ||
| Required chimney draught | Pa / mbar | 10 / 0, 10 | 12 / 0, 12 | 14 / 0, 14 | 26 / 0, 26 | 30 / 0, 30 | ||
| Insulation | Boiler | High-efficiency heat-resistant insulation wool | ||||||
| Doors | ||||||||
| Electrical power | Burner | WBS boiler | W | 60 | 60 | 60 | 60 | 60 |
| consumption | Pell | During ignition | ~ 400 | ~ 400 | ~ 400 | ~ 400 | ~ 400 | |
| During operation | ~ 60÷70 | ~ 60÷70 | ~ 60÷70 | ~ 60÷70 | ~ 60÷70 | |||
| During self-cleaning | ~ 1300 | ~ 1300 | ~ 1300 | ~ 1300 | ~ 1300 | |||
| Supply voltage | V / Hz | 230 / 50 | 230 / 50 | 230 / 50 | 230 / 50 | 230 / 50 | ||
| Recommended fuel | Pellets of class ENplus-A1, ENplus-A2 or EN-B | |||||||
| Operating temperature range | °C | 65 – 80 | 65 – 80 | 65 – 80 | 65 – 80 | 65 – 80 | ||
| Operating pressure | bar | 3 | 3 | 3 | 3 | 3 | ||
| Weight: boiler, burner / hopper | kg | 309 / 71 | 384 / 71 | 414 / 71 | 496 / 71 | 538 / 71 | ||
| Cold water inlet | A, mm | R1¼“ / 232 | R1¼“ / 232 | R1¼“ / 232 | R1¼“ / 232 | R1¼“ / 232 | ||
| Hot water outlet | B, mm | R1¼“ / 1265 | R1¼“ / 1265 | R1¼“ / 1265 | R1½“ / 1420 | R1½“ / 1420 | ||
| Sensor or safety valve socket | K, mm | G½“ / 1075 | G½“ / 1075 | G½“ / 1075 | G½“ / 1225 | G½“ / 1225 | ||
| Safety heat exchanger inlet / outlet | E, mm | R½“ / 1072 | R½“ / 1072 | R½“ / 1072 | R½“ / 1222 | R½“ / 1222 | ||
| Flue connection | F ø mm J, mm | 150 | 180 | 180 | 200 | 200 | ||
| 945 | 930 | 930 | 1065 | 1065 | ||||
| 270 | 350 | 350 | 350 | 380 | ||||
| Flue inspection opening | O, mm | 150 / 70 | 150 / 70 | 150 / 70 | 150 / 70 | 150 / 70 | ||
| Drain | Y, mm | G½“ / 232 | G½“ / 232 | G½“ / 232 | G½“ / 232 | G½“ / 232 |
CONSULTATION
Have questions about the product?