WBS Active boiler and Pell burner kit

WBS Active boiler with a fitted Pell pellet burner for heating medium and large rooms using wood pellets. The boiler is adapted for pellet combustion with additional components that help the kit reach the required efficiency. Tested and approved to EN 303-5, class 5.

Key features

Automatic ignition and pellet feed

Ready-to-use pellet boiler kit

Microprocessor controller

Temperature sensor

3 bar safety valve

WBS Active – Pell boiler components:

  1. Casing
  2. High-efficiency insulation
  3. Three-pass flue gas path
  4. Water jacket
  5. Combustion chamber
  6. Tray
  7. Burner flange
  8. Chimney
  9. Non-return damper fitted to the fan

Benefits

  • Ready-to-use pellet boiler kit.
  • WBS Active boiler adapted for pellet combustion with a fitted Pell burner, turbulators, an upper safety door and a mounting kit.
  • Self-cleaning burner function.
  • Heating system pump control.
  • Domestic hot water pump control.
  • Control via an external room thermostat.
  • Boiler control based on buffer tank temperature.
  • A temperature sensor monitors the boiler and the hot water cylinder.
  • Two temperature sensors monitor buffer tank temperature.

The kit includes:

1 – WBS AC boiler
2 – Pell pellet burner
3 – Pellet feed auger
4 – Mounting kit

Available outputs, kW:

KIT CONTENTS
BURNIT WBS AC PELLET 20  WBS AC 30 / PELL 30
BURNIT WBS AC PELLET 25  WBS AC 40 / PELL 30
BURNIT WBS AC PELLET 35  WBS AC 50 / PELL 40
BURNIT WBS AC PELLET 50  WBS AC 70 / PELL 70
BURNIT WBS AC PELLET 60  WBS AC 90 / PELL 70
BURNIT WBS AC PELLET 60 +  WBS AC 90 + / PELL 70

Safety components:

  • The curved burner feed tube prevents burn-back into the pellet hopper
  • Thermostatic protection (80°C)
  • 10 A fuse
  • If power is interrupted, all settings are retained in the controller memory
  • Safety heat exchanger
  • 3 bar safety valve

FULL MODEL SPECIFICATIONS

Technical specifications

Technical specificationsWBS – A 30WBS – AC 40WBS – AC 50WBS – AC 70WBS – AC 90
Pell 30Pell 30Pell 40Pell 70Pell 70
Rated outputkW2230355260
Min. / max. outputkW6÷259÷3210÷4015÷6518÷65
Flue gas mass flow,kg / s0, 005÷0, 0130, 011÷0, 0250, 007÷0, 0210, 012÷0, 0320, 010÷0, 031
at min. / max. output
Overall dimensions ofHeight Hmm12351235123513851385
WBS Active + PellWidth L540700700700760
Depth D13151315137514951495
Water jacket volumeL7596106134145
Combustion chamber volumeL628497120133
Water jacket resistance, Δt=20 KPa / mbar9 / 0, 0912 / 0, 1214 / 0, 1426 / 0, 2620 / 0, 20
Required chimney draughtPa / mbar10 / 0, 1012 / 0, 1214 / 0, 1426 / 0, 2630 / 0, 30
InsulationBoilerHigh-efficiency heat-resistant insulation wool
Doors
Electrical powerBurnerWBS boilerW6060606060
consumptionPellDuring ignition~ 400~ 400~ 400~ 400~ 400
During operation~ 60÷70~ 60÷70~ 60÷70~ 60÷70~ 60÷70
During self-cleaning~ 1300~ 1300~ 1300~ 1300~ 1300
Supply voltageV / Hz230 / 50230 / 50230 / 50230 / 50230 / 50
Recommended fuelPellets of class ENplus-A1, ENplus-A2 or EN-B
Operating temperature range°C65 – 8065 – 8065 – 8065 – 8065 – 80
Operating pressurebar33333
Weight: boiler, burner / hopperkg309 / 71384 / 71414 / 71496 / 71538 / 71
Cold water inletA, mmR1¼“ / 232R1¼“ / 232R1¼“ / 232R1¼“ / 232R1¼“ / 232
Hot water outletB, mmR1¼“ / 1265R1¼“ / 1265R1¼“ / 1265R1½“ / 1420R1½“ / 1420
Sensor or safety valve socketK, mmG½“ / 1075G½“ / 1075G½“ / 1075G½“ / 1225G½“ / 1225
Safety heat exchanger inlet / outletE, mmR½“ / 1072R½“ / 1072R½“ / 1072R½“ / 1222R½“ / 1222
Flue connectionF ø mm J, mm150180180200200
94593093010651065
270350350350380
Flue inspection openingO, mm150 / 70150 / 70150 / 70150 / 70150 / 70
DrainY, mmG½“ / 232G½“ / 232G½“ / 232G½“ / 232G½“ / 232