WBS boiler and Pell burner kit

WBS boiler with a fitted Pell pellet burner for heating medium and large rooms using wood pellets. The boiler is adapted for pellet combustion with additional components that help the kit reach the required efficiency. Tested and approved to EN 303-5, class 5.

Key features

Automatic ignition and pellet feed

Ready-to-use pellet boiler kit

Microprocessor controller

Enamelled electric heating element

Temperature sensor

3 bar safety valve

Benefits

  • Ready-to-use pellet boiler kit.
  • WBS boiler adapted for pellet combustion with a fitted Pell burner, turbulators, an upper safety door and a mounting kit.
  • Self-cleaning burner function.
  • Heating system pump control.
  • Domestic hot water pump control.
  • Control via an external room thermostat.
  • Boiler control based on buffer tank temperature.
  • A temperature sensor monitors the boiler and the hot water cylinder.
  • Two temperature sensors monitor buffer tank temperature.

The kit includes:

1 – WBS boiler
2 – Pell pellet burner
3 – Pellet feed auger
4 – Mounting kit

Available outputs, kW:

KIT CONTENTS
BURNIT WBS PELLET 20  WBS 30 / PELL 30
BURNIT WBS PELLET 25  WBS 40 / PELL 30
BURNIT WBS PELLET 35  WBS 50 / PELL 40
BURNIT WBS PELLET 50  WBS 70 / PELL 70
BURNIT WBS PELLET 60  WBS 90 / PELL 70
BURNIT WBS PELLET 60 +  WBS 90 + / PELL 70

 

Safety components:

  • The curved burner feed tube prevents burn-back into the pellet hopper
  • Thermostatic protection (80°C)
  • 10 A fuse
  • If power is interrupted, all settings are retained in the controller memory
  • Safety heat exchanger
  • 3 bar safety valve

WBS – Pell boiler components:

  1. Casing
  2. High-efficiency insulation
  3. Three-pass flue gas path
  4. Water jacket
  5. Combustion chamber
  6. Tray
  7. Burner flange
  8. Chimney
  9. Inspection opening

FULL MODEL SPECIFICATIONS

Technical specifications

WBS 30 - Pell 30WBS 40 - Pell 30WBS 50 - Pell 40WBS 70 - Pell 70WBS 90 - Pell 70WBS 90 PLUS - Pell 70
Rated powerkW223035526070
Min. / max. outputkW6÷259÷3210÷4015÷6518÷6520÷70
Flue gas mass flow,kg/s0,005÷0,0130,011÷0,0250,007÷0,0210,012÷0,0320,010÷0,0310,010÷0,032
min. / max. outputmm114511451145128512851285
Overall dimensions ofHeight H
WBS + PellWidth Ll464624624624684744
Depth D133013301390151015101510
Water jacket volume7596106134145162
Combustion chamber volumel628497120133212
Water jacket resistance, Δt=20, KPa/mbar9/0,0912/0,1214/0,1426/0,2620/0,2028/0.28
Required chimney draughtPa/mbar10/0,1012/0,1214/0,1426/0,2630/0,3030/0,30
InsulationBoilerHigh-efficiency heat-resistant wool
Doors
PowerBurnerWBS boilerW606060606060
of electrical componentsPellDuring ignitionV/Hz~ 400~ 400~ 400~ 400~ 400~ 400
During operation~ 60÷70~ 60÷70~ 60÷70~ 60÷70~ 70÷110~ 70÷110
In self-cleaning mode~ 1300~ 1300~ 1300~ 1300~ 1300~ 1300
Supply voltage230/50230/50230/50230/50230/50230/50
Recommended fuelPellets, ENplus-A1; ENplus-A2; EN-B
Operating temperature range°C65 – 8065 – 8065 – 8065 – 8065 – 8065-80
Operating pressurebar333333
Weight: boiler, burner / hopperkg309/71384/71414/71496/71538/71568/71
Cold water inletA, mmR1¼“/232R1¼“/232R1¼“/232R1¼“/232R1¼“/232R1½“/232
Hot water outletB, mmR1¼“/1265R1¼“/1265R1¼“/1265R1½“/1420R1½“/1420R1½“/1420
Socket for sensor or safety valveK, mmG½“/1075G½“/1075G½“/1075G½“/1225G½“/1225G½“/1225
Safety heat exchanger inlet/outletE, mmR½“/1072R½“/1072R½“/1072R½“/1222R½“/1222R½“/1222
ChimneyF ø,mm J, mm150180180200200200
Chimney inspection openingO, mm945930930106510651065
270350350350380380
150/70150/70150/70150/70150/70150/70
DrainY, mmG½“/232G½“/232G½“/232G½“/232G½“/232G½“/232

CONSULTATION

Have questions about the product?

Contact our specialist for a quotation and technical advice.